HOW qEV COMPARES

Not All SEC Columns Are Built the Same.

qEV Gen 2 columns use Izon-exclusive SEC resin to deliver higher EV purity and recovery than columns using off-the-shelf resins. Manufactured under ISO 13485, they underpin the world’s most established and scalable EV isolation platform.

~99% protein removed

qEV Gen 2 columns gently remove approximately 99% of soluble protein from human plasma.

Higher EV recovery

Purity gains without a recovery trade-off: Gen 2 recovers significantly more EVs than comparable columns.

Built for clinical translation

Consumable qEV columns are manufactured under a quality management system certified to ISO 13485:2016, with GMP-ready columns available.

Get the Purest EV Isolates Possible

qEV Gen 2 columns, built using Izon-exclusive SEC resin, deliver significantly higher EV purity than columns using standard market resins (CL-4B and CL-2B) — resins Izon's own Legacy columns also once relied on.

qEV Gen 2 columns gently remove ~99% of soluble protein from human plasma.

EV purity: qEV Gen 2 columns vs comparable SEC resinsEVs and similarly sized particles above 60 nm recovered per microgram of protein, for qEV Gen 2 35 nm and 70 nm columns against CL-4B and CL-2B resins.
EV purity is presented as the particle-to-protein ratio, measured using TRPS and BCA assay. CL-4B and CL-2B are SEC resins used broadly across the EV isolation market — including in Izon's own Legacy 35 nm and 70 nm columns, since replaced by qEV Gen 2.

Maximise EV Recovery

When developing the qEV Gen 2 column range, we engineered every aspect of the design for EV isolation, including an exclusive resin optimised specifically for extracellular vesicles.

The result is significantly higher EV recovery than comparable SEC columns.

EV recovery: qEV Gen 2 columns vs comparable SEC columnsParticle recovery of qEV Gen 2 against comparable SEC columns.
Particle recovery of qEV Gen 2 against comparable SEC columns.

Lipoprotein Depletion, Covered

qEV Gen 2 columns remove the vast majority of lipoproteins from human plasma — without a separate binding resin step.

That means a cleaner isolate, without the recovery trade-off that comes with dual-mode chromatography. We tested that approach years ago and moved away from it: binding resins strip out lipoproteins, but at the cost of losing EVs along with them.

Remove ~99% of ApoB with all qEV columns, and achieve >99.99% removal of ApoA1 with the 70 nm series.

ApoB depletion: qEV Gen 2 columns vs comparable SEC resins
Lipoprotein carry-over in qEV Gen 2 isolates from human plasma.

What About the 20 nm Series?

Our 20 nm range launched after Gen 2, extending isolation down to smaller EV populations. Since it wasn't part of the original Gen 2 resin upgrade, it isn't included in the comparisons above — but you can see its purity and recovery data on the dedicated qEV Series comparison page.

EV recovery across the qEV Gen 2 range and comparable columns
Particle recovery of the qEV 20 nm series alongside qEVoriginal and comparable columns.

Built for Clinical Translation

qEV column production has been refined through a precise, proprietary packing technique and protocols guided by a quality management system certified to ISO 13485:2016. For clinical and cGMP workflows, our GMP-ready qEV columns take that consistency further:

  • Manufactured under rigorous quality control, with Certificates of Analysis documenting compliance
  • Column filling uses aseptic methods, with final sanitisation steps to control bioburden and endotoxin levels
  • Made to order, and paired with qEV Automation models for cGMP environments

Start a Conversation About Your Research

Resources

How much does EV isolation process development and sample processing cost?

To give you an idea, you can outsource your EV isolation scale-up of ~6-10 L batches for a very competitive cost of ~25K USD. To discuss the cost of tech transfer and for other volume ranges, talk to the team.

Where can samples be processed?

Currently, this service is run from our facilities in Boston and in Lyon. If you are based outside the US or Europe, let us know your requirements to see what we can do.

What sample volumes do you work with?

In addition to being the leading provider of EV isolation solutions for sample volumes from 150 µL to 100 mL, we have recently processed samples for customers ranging from 1 to 2000 L starting volumes! For those scaling in volume, we have found that the 6-10 L range serves as a practical volume for feasibility studies, where it makes sense to optimise around this range before going much larger.

What sample types do you work with?

The principles of sample preparation and isolation remain the same for most sample types. Therefore, we are open to whatever project you have in mind – just reach out to the team to confirm it will be a good fit.